Sensepoint XCD Transmitter (without Sensor)
Honeywell SPXCDULNFXM Sensepoint XCD Fixed Industrial Gas Detectors Flammable CAT 0-100%LEL with Modbus

Honeywell SPXCDULNFXM Sensepoint XCD Fixed Industrial Gas Detectors Flammable CAT 0-100%LEL with Modbus

Model: Honeywell SPXCDULNFXM Sensepoint XCD Fixed Industrial Gas Detectors Flammable CAT 0-100%LEL with Modbus

$0.00

Supplier: Honeywell

Categories: Sensepoint XCD Transmitter (without Sensor)

After sales service. If you have any questions, click here.

Product Description

Honeywell SPXCDULNFXM Sensepoint XCD Fixed Industrial Gas Detectors Flammable CAT 0-100%LEL with Modbus

 

Honeywell SPXCDULNFXM Sensepoint XCD Fixed Industrial Gas Detectors Flammable CAT 0-100%LEL with Modbus

Honeywell SPXCDULNFXM Sensepoint XCD Fixed Industrial Gas Detectors Flammable CAT 0-100%LEL with Modbus

UL approved SP XCD Flammable CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with LM25, 3/4"NPT Entry, with Modbus.

 

Sensepoint XCD is easy to use. The sensor simply plugs into the bottom of the transmitter and the transmitter automatically configures itself accordingly. Users can modify detector operation using the LCD and magnet switches without ever needing to open the unit. This enables one-man, non-intrusive operation and reduces routine maintenance time and costs.

 

A tri-color backlit LCD clearly indicates the unit’s status at a glance, even from a distance. A steady green backlight indicates normal operation, flashing yellow indicates fault and flashing red indicates an alarm.

 

All detectors are supplied pre-configured and include two programmable alarm relays, one programmable fault relay as well as an industry standard 4-20mA output (sink or source selectable) and MODBUS communication. The scale, range, relay operation, alarm set point and electronic tag number of the detector can be adjusted using the transmitter's LCD and non-intrusive magnetic switches. Outputs are automatically inhibited during adjustment, thereby reducing the risk of false alarm at the control panel during maintenance.

 

 

 

Additional Features and Benefits: 

All-In-One Gas Monitoring Solution 

  • Flammable (catalytic or infrared), toxic and oxygen versions available  

  • Serves new/retrofit, indoor/outdoor applications  

  • Stainless steel or aluminum explosion-proof housing options  

  • IP66 as standard 

Proven and Reliable Sensor Technology 

  • SurecellTM electrochemical sensors  

  • Poison immune infrared sensors  

  • Poison resistant catalytic bead sensors  

  • Long life sensors 

Global Approvals 

  • US and Latin America, European, Canadian and Asian  

  • Compliant with UL, INMETRO, ATEX,  IECEx, CSA, KTL, PA, GB and CCCF standards 

Easy to Use  

  • User friendly and intuitive tri-color backlit display with digits, bar graph and icons  

  • Fully configurable via magnetic switches  

  • Optional remote sensor mounting  

  • Selectable sink or source 4-20mA output  

  • Auto-inhibit during maintenance  

  • MODBUS communications for remote diagnostics/configuration 

Cost Effective  

  • Common transmitter platform  

  • Minimal training required  

  • Reduced spares  

  • Non-intrusive, one-man operation  

  • Plug-in sensor replacement  

  • MODBUS multi drop option offers cabling savings 

Simple Installation  

  • Plug-in display module removes to give access to terminal area  

  • Integral mounting bracket  

  • 2 x M20 or ¾” NPT cable/conduit entries                      

  • Removable plug/socket type terminal blocks for               

  • Sink/source switch to suit preferred wiring topology  

  • Integral mounting plate attaches to surface, horizontal or vertical piping

 

UL APPROVAL (Epoxy Coated Aluminium Alloy, LM25)

 

SPXCDULNFX UL approved SP XCD Flammable CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with
LM25, 3/4"NPT Entry

SPXCDULNRX UL approved SP XCD CH4(Methane) IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with
LM25, 3/4"NPT Entry

SPXCDULNPX UL approved SP XCD C3H8(Propane) IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL)
with LM25, 3/4"NPT Entry

SPXCDULNO1 UL approved SP XCD Oxygen 25.0%/Vol with LM25, 3/4"NPT Entry $921.00
SPXCDULNHX UL approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25,
3/4"NPT Entry

SPXCDULNCX UL approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with
LM25, 3/4"NPT Entry

SPXCDULNG1 UL approved SP XCD Hydrogen 0-1000ppm with LM25, 3/4"NPT Entry 
SPXCDULNNX UL approved SP XCD Nitrogen Dioxide 0-50ppm with LM25, 3/4"NPT Entry 
SPXCDULNB1 UL approved SP XCD Carbon Dioxide IR 0-2%VOL with LM25, 3/4"NPT Entry 
SPXCDULNB2 UL approved SP XCD Carbon Dioxide IR 0-5%VOL with LM25, 3/4"NPT Entry


UL APPROVAL (Epoxy Coated Stainless Steel, SS316)

 

SPXCDUSNFX UL approved SP XCD Flammable CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with
SS316, 3/4"NPT Entry

SPXCDUSNRX UL approved SP XCD CH4(Methane) IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with
SS316, 3/4"NPT Entry

SPXCDUSNPX UL approved SP XCD C3H8(Propane) IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL)
with SS316, 3/4"NPT Entry

SPXCDUSNO1 UL approved SP XCD Oxygen 25.0%/Vol with SS316, 3/4"NPT Entry $1,126.00
SPXCDUSNHX UL approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with
SS316, 3/4"NPT Entry

SPXCDUSNCX UL approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with
SS316, 3/4"NPT Entry

SPXCDUSNG1 UL approved SP XCD Hydrogen 0-1000ppm with SS316, 3/4"NPT Entry 
SPXCDUSNNX UL approved SP XCD Nitrogen Dioxide 0-50ppm with SS316, 3/4"NPT Entry 
SPXCDUSNB1 UL approved SP XCD Carbon Dioxide IR 0-2%VOL with SS316, 3/4"NPT Entry
SPXCDUSNB2 UL approved SP XCD Carbon Dioxide IR 0-5%VOL with SS316, 3/4"NPT Entry

 

UL APPROVAL (Epoxy Coated Aluminium Alloy, LM25. With Modbus)

 

SPXCDULNFXM UL approved SP XCD Flammable CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with
LM25, 3/4"NPT Entry, with Modbus.

SPXCDULNRXM UL approved SP XCD CH4(Methane) IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with
LM25, 3/4"NPT Entry, with Modbus.

SPXCDULNPXM UL approved SP XCD C3H8(Propane) IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL)
with LM25, 3/4"NPT Entry, with Modbus.

SPXCDULNO1M UL approved SP XCD Oxygen 25.0%/Vol with LM25, 3/4"NPT Entry, with Modbus. $973.00
SPXCDULNHXM UL approved SP XCD Hydrogen Sulfide 0-50ppm (10.0 to 100.0ppm, 1ppm) with LM25,
3/4"NPT Entry, with Modbus.

SPXCDULNCXM UL approved SP XCD Carbon Monoxide 0-300ppm (100 to 1000ppm, 100ppm) with
LM25, 3/4"NPT Entry, with Modbus.

SPXCDULNG1M UL approved SP XCD Hydrogen 0-1000ppm with LM25, 3/4"NPT Entry, with Modbus. $973.00
SPXCDULNNXM UL approved SP XCD Nitrogen Dioxide 0-50ppm with LM25, 3/4"NPT Entry, with
Modbus.

SPXCDULNB1M UL approved SP XCD Carbon Dioxide IR 0-2%VOL with LM25, 3/4"NPT Entry, with
Modbus.

SPXCDULNB2M UL approved SP XCD Carbon Dioxide IR 0-5%VOL with LM25, 3/4"NPT Entry, with
Modbus.

 

--------------------------------------------------------------------------

Any inquiry,Please feel free to contact:

Windy Wang  
windy@hkxytech.com
HONGKONG XIEYUAN TECH CO., LIMITED  
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006



Related Products