Warning: include(/www/wwwroot/www.hkxyauto.com/_data/tpl_www/1_head.php): failed to open stream: Permission denied in /www/wwwroot/www.hkxyauto.com/framework/phpok_tpl.php on line 206

Warning: include(): Failed opening '/www/wwwroot/www.hkxyauto.com/_data/tpl_www/1_head.php' for inclusion (include_path='.:/www/server/php/56/lib/php') in /www/wwwroot/www.hkxyauto.com/framework/phpok_tpl.php on line 206
Pepperl+Fuchs
Pepperl+Fuchs FieldBarrier RD0-FB-Ex4 In Good Price With Ready Stock

Pepperl+Fuchs FieldBarrier RD0-FB-Ex4 In Good Price With Ready Stock

Model: RD0-FB-Ex4

$1.00

Supplier: Products

Categories: Pepperl+Fuchs

After sales service. If you have any questions, click here.

Product Description

Pepperl+Fuchs FieldBarrier RD0-FB-Ex4 In Good Price With Ready Stock


Features of RD0-FB-Ex4

• 4 outputs Ex ia IIC

• FieldBarrier in Zone 1/Div. 2

• Instruments in Zone 0...1/Div. 1

• Short circuit current limitation per output

• For FOUNDATION Fieldbus H1 and PROFIBUS PA

• Power, Com, and Error LEDs

• Supports FISCO and Entity

• Integrated cable tie-downs

• Supports all grounding methods


p+f rdo-fb-ex-4_副本


General specifications of RD0-FB-Ex4

Design / Mounting Cabinet installation

Fieldbus interface

Main cable (Trunk) 

Connection input (Trunk IN): terminals 3+, 4-, 5s

output (Trunk OUT): terminals 7-, 8+, 6s

Rated voltage 32 ... 16 V DC

Rated current 31 mA ... 26 mA (without load)

77 mA ... 115 mA (at 20 mA load per input)

120 mA ... 209 mA (at 40 mA load per input)

135 mA ... 241 mA (short-circuit on all outputs)

Voltage drop trunk IN to trunk OUT 100 mV max.

Number of couplers max. 4 per segment

Outputs 

Number of devices per output 1

Connection output 1: terminals 10+, 11-, 12S shield; 

output 2: terminals 13+, 14-, 15S shield; 

output 3: terminals 16+, 17-, 18S shield; 

output 4: terminals 19+, 20-, 21S shield

Rated voltage 10 ... 13 V

Rated current ≤ 43 mA

Short-circuit current 50 mA

Terminating impedance 100 Ω switchable

Indicators/operating means

LED voltage Fieldbus green: on, bus voltage existent

LED status output red flashing: short-circuit

Galvanic isolation

Main wire/outputs isolation is not affected by interference according to EN 50020, voltage peak value 375 V

Directive conformity

Electromagnetic compatibility 

Directive 2014/30/EU EN 61326-1:2013

Standard conformity

Electromagnetic compatibility NE 21:2006

Degree of protection IEC/EN 60529

Fieldbus standard IEC 61158-2

Climatic conditions DIN IEC 721

Corrosion resistance acc. to ISA-S71.04-1985, severity level G3

Ambient conditions

Ambient temperature -50 ... 70 °C (-58 ... 158 °F)

Storage temperature -40 ... 85 °C (-40 ... 185 °F)

Mechanical specifications

Connection type fixed terminals, plug-in terminals

Core cross-section up to 2.5 mm2

Housing see figure 1

Housing material Polycarbonate

R... DIN rail housing PA 6.6

Degree of protection IP20

Mass 1050 g

Mounting mounting on DIN rail in cabinet

Data for application in connection 

with hazardous areas

EU-Type Examination Certificate PTB 02 ATEX 2086

Marking ¬ II 2 (1) G Ex eb mb [ia Ga] IIC T4 Gb ,

¬ II (1) D [Ex ia Da] IIIC

Main cable (Trunk) 

Maximum safe voltage Um 253 V AC

Outputs 

Power Po 975 mW

Voltage Uo 15.75 V

Current Io 248 mA

Directive conformity 

Directive 2014/34/EU EN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-18:2015 , EN 60079-31:2013

International approvals

FM approval CoC 3015728

Control drawing No. 116-0226

Approved for Class I, Division 2, Groups A, B, C, D / Class I, Zone 2, AEx nA [ia] IIC T4

image

image

R4D0-FB-IA*

FieldBarrier® for Cabinet Installation

FieldConnex® FieldBarrier®, 8 ... 12 outputs Ex ia IIC, FISCO and Entity, Advanced fault isolation and diagnostics at the spur, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Dust protection, International, Europe, USA, Device coupler location: Zone 2 - high-power trunk

Zone 1 - high-power trunk

Division 2 - high-power trunk

Division 1 - high-power trunk


R8D0-MIO-Ex12.FF*

Multi-Input/Output Device for Cabinet Installation

For discrete inputs and outputs, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1, IECEx approval, Dust protection, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area

Zone 2 - high-power trunk

Zone 1 - high-power trunk

Division 2 - high-power trunk

Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunk


R8D0-MIO-Ex12.PA*

Multi-Input/Output Device for Cabinet Installation

For discrete inputs and outputs, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA, IECEx approval, Dust protection, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area

Zone 2 - high-power trunk

Zone 1 - high-power trunk

Division 2 - high-power trunk

Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunk


RD0-FB-Ex4.*

FieldBarrier®

4 outputs Ex ia IIC, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, Short circuit current limitation per output, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Dust protection, International, Europe, USA, Canada, Device coupler location: Zone 2 - high-power trunk

Zone 1 - high-power trunk

Division 2 - high-power trunk

Division 1 - high-power trunk, Device coupler location [2]: Zone 1 - high-power trunk


RD0-TI-Ex8.FF.*

Temperature Multi-Input Device for Cabinet Installation

For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1, IECEx approval, Dust protection, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area

Zone 2 - high-power trunk

Zone 1 - high-power trunk

Division 2 - high-power trunk

Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunk


RD0-TI-Ex8.PA.*

Temperature Multi-Input Device for Cabinet Installation

For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For PROFIBUS PA, IECEx approval, Dust protection, Europe, USA, Canada, Device coupler location: non-explosion hazardous area

Zone 2 - high-power trunk

Zone 1 - high-power trunk

Division 2 - high-power trunk

Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunk


SCP-LBF-IA1.36.IE*

Pluggable, mounts between device coupler and spur cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Europe, USA, Canada, Device coupler location: non-explosion hazardous area

Zone 2 - high-power trunk

Zone 1 - high-power trunk

Division 2 - high-power trunk

Division 1 - high-power trunk


SPJB-**-AL*.***

Segment Protector Junction Box, Aluminum

Intrinsically safe (Ex ic)/non-incendive outputs, Anodized aluminum, IP67, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA, USA, Canada, Device coupler location: Division 2 - high-power trunk, Instrument location / spur protection: Division 2 - all relevant types of protection, Function: Device coupler, Design / Mounting: Outside installation


SPJB-**-CS*.***

Segment Protector Junction Box, Carbon Steel

Intrinsically safe (Ex ic)/non-incendive outputs, Carbon steel, NEMA 4, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA, USA, Canada, Device coupler location: Division 2 - high-power trunk, Instrument location / spur protection: Division 2 - all relevant types of protection, Function: Device coupler, Design / Mounting: Outside installation


SPJB-**-FB*.***

Segment Protector Junction Box, Polyester (GRP)

Intrinsically safe (Ex ic)/non-incendive outputs, Glass fiber reinforced polyester, NEMA 4x, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA, USA, Canada, Device coupler location: Division 2 - high-power trunk, Instrument location / spur protection: Division 2 - all relevant types of protection, Function: Device coupler, Design / Mounting: Outside installation


SPJB-**-PCW.***

Segment Protector Junction Box, Polycarbonate

Intrinsically safe (Ex ic)/non-incendive outputs, Impact resistant polycarbonate, NEMA 4x, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA, USA, Canada, Device coupler location: Division 2 - high-power trunk, Instrument location / spur protection: Division 2 - all relevant types of protection, Function: Device coupler, Design / Mounting: Outside installation


SPJB-**-SS*.***

Segment Protector Junction Box, Stainless Steel

Intrinsically safe (Ex ic)/non-incendive outputs, Stainless steel, brushed NEMA 4x, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA, USA, Canada, Device coupler location: Division 2 - high-power trunk, Instrument location / spur protection: Division 2 - all relevant types of protection, Function: Device coupler, Design / Mounting: Outside installation


TCP-LBF-IA1.36.IE*

Fieldbus Surge Protector, Field Installation on Trunk


Pluggable, mounts between device coupler and trunk cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Europe, USA, Canada, Device coupler location: non-explosion hazardous area

Zone 2 - high-power trunk

Zone 1 - high-power trunk

Division 2 - high-power trunk

Division 1 - high-power trunk


TPH-LBF-IA1.36.DE*

Fieldbus Surge Protector, Trunk Installation on Power Hub


Pluggable, mounts between Power Hub and trunk cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield direct, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Europe, USA, Canada, Device coupler location: non-explosion hazardous area

Zone 2 - high-power trunk

Zone 1 - high-power trunk

Division 2 - high-power trunk

Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunk


ABOUT US


HONGKONG XIEYUAN TECH CO.,LTD, established in 7th Nov.,2012, a comprehensive corporation with its independent rights of export and import.. We are committed to providing customers with convenient and efficient industrial supplies services. From the product, price, logistics, service process for customers to improve procurement efficiency, reduce procurement costs, and grow together with customers.

 

Xieyuan sales of major brands are: Yokogawa, Siemens, ABB, Schneider, Emerson, Rosemount, Honeywell, Pepper+Fuchs, MTL, Fluke, Fisher, Endress+Hauser, Phoenix Contact, Weidmüller, Triconex, KROHNE, Dräger, Allen-Bradley, Omron, Eaton, SMC, Eaton, RAE, Testo, MSA, FESTO, Vega, Yaskawa, Danfoss, GE, Fisher, Hirschmann, IFM, Turck, MOXA, Foxboro etc.


Our wide range of products include Field Instruments, Field Communicator, Gas Detectors, Process Analyzers, Pressure Transmitters, Temperature Transmitters, Flow Meters, Inverters, Multimeters, Safety Barriers, Positioners, Controllers, Valves, Circuit Breakers, Sensors, DCS, PLC etc.


We endeavor to provide our customer with high quality, 100% original brand new products at competitive prices. Our targeting market includes Oil and Gas Industry, Refinery, Chemical, Mineral, Power and Energy, Ocean Engneering, Electricity, Food, Environment Protection and many other fields. 


We operate in more than 50 countries around the world. There are: Singapore, Indonesia, Malaysia, Philippines, Vietnam, Thailand, South Korea, Kazakhstan, Bangladesh, United Arab Emirates, Saudi Arabia, Iran, Iraq, Kuwait, Oman, Qatar,Germany, Italy, Austria, UK, Nigeria, Pakistan, Egypt, USA, Chile, Brazil, Mexico etc.



CHINA MAINLAND ADDRESS:

7-A16,CAISHEN COMMERCIAL PLAZA, HANKOU RAILWAY STATION, WUHAN, CHINA.


All products will send out within 72 hours, Please feel free to contact us! Thanks 


Windy Wang 
HONGKONG XIEYUAN TECH CO., LIMITED  
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com 
Website:  http://www.hkxytech.com/   | GMT/UTC +8



Related Products