Honeywell S2-R-Y BW™ Solo Serviceable Single-Gas Detector With Good Price In Stock
Honeywell BW™ S2-R-Y Solo Lite – hydrogen (H2) BW
Honeywell BW™ Solo Lite – hydrogen (H2) BWS2-R-Y BWS2-R-B
The Honeywell BW™ Solo is easy to operate and service and includes an extensive selection of sensor options. It can help reduce the cost of ownership for serviceable single-gas detectors and includes a wireless option for enabling connected workers. The profile is small and lightweight, and the design is ruggedized for years of reliable service. No need to take apart the Honeywell BW™ Solo for common maintenance tasks; simply pop off the front door to replace a sensor or filter, or remove a single screw for battery replacement. Optional wireless connectivity enables additional capabilities such as dock-less transfer of data and event logs, and real-time monitoring of worker safety.
Honeywell BW Solo Hydrogen Gas Detector measures H2 from 0 to 1000ppm. Honeywell BW Solo Gas Detector H2 screen provides a real-time digital display of gas concentrations while vibrating, audible and flashing alarms warn of potential danger.Honeywell BW™ S2-R-Y Solo Lite – hydrogen (H2) BW
Honeywell BW™ Solo is a easy to service single-gas detector with BLE connectivity that provides real-time visibility into the status and safety of hazardous-area workers, helping companies respond faster, more knowingly and decisively to safety incidents.Honeywell BW™ S2-R-Y Solo Lite – hydrogen (H2) BW
User-friendly operation
Easy-to-read display for multiple languages
Lightweight convenience
Ease of maintenance
Serviceability
The new 1-Series sensor for enhanced reliability
Connected Bluetooth Low Energy (BLE) capabilities
High standards of sensor quality and reliability
The easiest single-gas detector to service
The first single-gas detector with the 1 Series sensor for CO, H2S and O2
Complete with an extensive selection of sensor options
Compatible with IntelliDoX
Detectors arrive ready for use with concussion-proof housing, sensor(s), field replaceable battery, stainless steel alligator clip, calibration/test cap and hose, instructions and quick reference card.
Measuring Range: 0-1000 ppm (Honeywell BW™ S2-R-Y Solo Lite – hydrogen (H2) BW)

Honeywell BW™ S2-R-Y Solo Lite – hydrogen (H2) BW
| Honeywell BW™ Solo, non-wireless – chlorine (Cl2) |
| BWS-C-Y |
| BWS-C-B |
| Honeywell BW™ Solo, non-wireless – chlorine dioxide (ClO2) |
| BWS-V-Y |
| BWS-V-B |
| Honeywell BW™ Solo, non-wireless – carbon monoxide (CO) |
| BWS-ML-Y |
| BWS-ML-B |
| Honeywell BW™ Solo, non-wireless – carbon monoxide, hydrogen (h2) resistant (CO-H) |
| BWS-M2-Y |
| BWS-M2-B |
| Honeywell BW™ Solo, non-wireless – ethylene oxide (ETO) |
| BWS-E-Y |
| BWS-E-B |
| Honeywell BW™ Solo, non-wireless – hydrogen (H2) |
| BWS-R-Y |
| BWS-R-B |
| Honeywell BW™ Solo, non-wireless – hydrogen sulfide (H2S) |
| BWS-HL-Y |
| BWS-HL-B |
| Honeywell BW™ Solo, non-wireless – hydrogen sulfide, extended range (H2S) |
| BWS-H2-Y |
| BWS-H2-B |
| Honeywell BW™ Solo, non-wireless – hydrogen cyanide (HCN) |
| BWS-Z-Y |
| BWS-Z-B |
| Honeywell BW™ Solo, non-wireless – ammonia (NH3) |
| BWS-A-Y |
| BWS-A-B |
| Honeywell BW™ Solo, non-wireless – ammonia, extended range (NH3) |
| BWS-A2-Y |
| BWS-A2-B |
| Honeywell BW™ Solo, non-wireless – nitric oxide (NO) |
| BWS-N-Y |
| BWS-N-B |
| Honeywell BW™ Solo, non-wireless – nitrogen dioxide (NO2) |
| BWS-D-Y |
| BWS-D-B |
| Honeywell BW™ Solo, non-wireless – oxygen (O2) |
| BWS-XL-Y |
| BWS-XL-B |
| Honeywell BW™ Solo, non-wireless – ozone (O3) |
| BWS-G-Y |
| BWS-G-B |
| Honeywell BW™ Solo, non-wireless – phosphine (PH3) |
| BWS-P-Y |
| BWS-P-B |
| Honeywell BW™ Solo, non-wireless – sulfur dioxide (SO2) |
| BWS-S-Y |
| BWS-S-B |
| Honeywell BW™ Solo Single-Gas Detector, Wireless Version |
| Honeywell BW™ Solo, wireless – chlorine (Cl2) |
| BWS1-C-Y |
| BWS1-C-B |
| Honeywell BW™ Solo, wireless – chlorine dioxide (ClO2) |
| BWS1-V-Y |
| BWS1-V-B |
| Honeywell BW™ Solo, wireless – carbon monoxide (CO) |
| BWS1-ML-Y |
| BWS1-ML-B |
| Honeywell BW™ Solo, wireless – carbon monoxide, hydrogen (h2) resistant (CO-H) |
| BWS1-M2-Y |
| BWS1-M2-B |
| Honeywell BW™ Solo, wireless – ethylene oxide (ETO) |
| BWS1-E-Y |
| BWS1-E-B |
| Honeywell BW™ Solo, wireless – hydrogen (H2) |
| BWS1-R-Y |
| BWS1-R-B |
| Honeywell BW™ Solo, wireless – hydrogen sulfide (H2S) |
| BWS1-HL-Y |
| BWS1-HL-B |
| Honeywell BW™ Solo, wireless – hydrogen sulfide (H2S), extended range |
| BWS1-H2-Y |
| BWS1-H2-B |
| Honeywell BW™ Solo, wireless – hydrogen cyanide (HCN) |
| BWS1-Z-Y |
| BWS1-Z-B |
| Honeywell BW™ Solo, wireless – ammonia (NH3) |
| BWS1-A-Y |
| BWS1-A-B |
| Honeywell BW™ Solo, wireless – ammonia (NH3), extended range |
| BWS1-A2-Y |
| BWS1-A2-B |
| Honeywell BW™ Solo, wireless – nitric oxide (NO) |
| BWS1-N-Y |
| BWS1-N-B |
| Honeywell BW™ Solo, wireless – nitrogen dioxide (NO2) |
| BWS1-D-Y |
| BWS1-D-B |
| Honeywell BW™ Solo, wireless – oxygen (O2) |
| BWS1-XL-Y |
| BWS1-XL-B |
| Honeywell BW™ Solo, wireless – ozone (O3) |
| BWS1-G-Y |
| BWS1-G-B |
| Honeywell BW™ Solo, wireless – phosphine (PH3) |
| BWS1-P-Y |
| BWS1-P-B |
| Honeywell BW™ Solo, wireless – sulfur dioxide (SO2) |
| BWS1-S-Y |
| BWS1-S-B |
| Honeywell BW™ Solo Lite – chlorine (Cl2) |
| BWS2-C-Y |
| BWS2-C-B |
| Honeywell BW™ Solo Lite – chlorine dioxide (ClO2) |
| BWS2-V-Y |
| BWS2-V-B |
| Honeywell BW™ Solo Lite – carbon monoxide (CO) |
| BWS2-M-Y |
| BWS2-M-B |
| Honeywell BW™ Solo Lite – carbon monoxide, hydrogen (h2) resistant (CO-H) |
| BWS2-M2-Y |
| BWS2-M2-B |
| Honeywell BW™ Solo Lite – ethylene oxide (ETO) |
| BWS2-E-Y |
| BWS2-E-B |
| Honeywell BW™ Solo Lite – hydrogen (H2) |
| BWS2-R-Y |
| BWS2-R-B |
| Honeywell BW™ Solo Lite – hydrogen sulfide (H2S) |
| BWS2-H-Y |
| BWS2-H-B |
| Honeywell BW™ Solo Lite – hydrogen sulfide (H2S), extended range |
| BWS2-H2-Y |
| BWS2-H2-B |
| Honeywell BW™ Solo Lite – hydrogen cyanide (HCN) |
| BWS2-Z-Y |
| BWS2-Z-B |
| Honeywell BW™ Solo Lite – ammonia (NH3) |
| BWS2-A-Y |
| BWS2-A-B |
| Honeywell BW™ Solo Lite – ammonia (NH3), extended range |
| BWS2-A2-Y |
| BWS2-A2-B |
| Honeywell BW™ Solo Lite – nitric oxide (NO) |
| BWS2-N-Y |
| BWS2-N-B |
| Honeywell BW™ Solo Lite – nitrogen dioxide (NO2) |
| BWS2-D-Y |
| BWS2-D-B |
| Honeywell BW™ Solo Lite – oxygen (O2) |
| BWS2-X-Y |
| BWS2-X-B |
| Honeywell BW™ Solo Lite – ozone (O3) |
| BWS2-G-Y |
| BWS2-G-B |
| Honeywell BW™ Solo Lite – phosphine (PH3) |
| BWS2-P-Y |
| BWS2-P-B |
| Honeywell BW™ Solo Lite – sulfur dioxide (SO2) |
| BWS2-S-Y |
| BWS2-S-B |
| Honeywell IntelliDoX® Automated Instrument Management System |
| Honeywell IntelliDoX® docking station for Honeywell BW™ Solo |
| DX-SOLO |
| Honeywell IntelliDoX® Nest for Honeywell BW™ Solo |
| DX-NEST-SOLO |
| Honeywell IntelliDoX® enabler kit, EU version (Europe) |
| DX-ENBL-UK |
| Honeywell IntelliDoX® enabler kit, UK version (United Kingdom) |
| DX-ENBL-EU |
| Honeywell IntelliDoX® enabler kit, NA version (North America) |
| DX-ENBL-NA |
| Honeywell BW邃「 Solo replacement battery |
| BWS-BAT01 |
| Honeywell BW邃「 Solo test/calibration cap |
| BWS-TC-1 |
| Neck strap with safety release |
| GA-NS-1 |
| Short strap (15.2 cm / 6 in.) |
| GA-LY-1 |
| Extension strap (1.2 m / 4 ft.) |
| GA-ES-1 |
| Chest harness |
| GA-CH-2 |
| Manual aspirator pump kit with probe (0.3 m / 1 ft.) |
| GA-AS02 |
| Replacement carbon monoxide (CO) sensor (1-Series) |
| SR-M1-1S |
| Replacement hydrogen sulfide (H2S) sensor (1-Series) |
| SR-H1-1S |
| Replacement oxygen (O2) sensor (1-Series) |
| SR-X1-1S |
| Replacement chlorine (Cl2) sensor (4-Series) |
| PS-RC10 |
| Replacement chlorine dioxide (ClO2) sensor (4-Series) |
| SR-V04 |
| Replacement carbon monoxide, hydrogen (h2) resistant (CO-H) sensor (4-Series) |
| 54-47-19 |
| Replacement ethylene oxide (ETO) sensor (4-Series) |
| SR-ER04 |
| Replacement hydrogen (H2) sensor (4-Series) |
| SR-RR04 |
| Replacement hydrogen sulfide (H2S), extended range sensor (4-Series) |
| PS-RH04S |
| Replacement hydrogen cyanide (HCN) sensor (4-Series) |
| SR-ZR04 |
| Replacement ammonia (NH3) sensor (4-Series) |
| SR-A04 |
| Replacement ammonia (NH3), extended range sensor (4-Series) |
| SR-A204 |
| Replacement nitric oxide (NO) sensor (4-Series) |
| SR-NR04 |
| Replacement nitrogen dioxide (NO2) sensor (4-Series) |
| PS-RD04 |
| Replacement ozone (O3) sensor (4-Series) |
| SR-G04 |
| Replacement phosphine (PH3) sensor (4-Series) |
| SR-P04 |
| Replacement sulfur dioxide (SO2) sensor (4-Series) |
| PS-RS04 |
| Replacement oxygen (O2) sensor (4-Series) |
| SR-X2V |
| Replacement hydrogen Sulfide (H2S) sensor (4-Series) |
| SR-H-4S |
| Replacement carbon monoxide (CO) sensor (4-Series) |
| SR-M-4S |
| Replacement battery cover kit, non-wireless |
| BWS-BH-1 |
| Replacement battery cover kit, wireless |
| BWS-BH-2 |
| – |
| Replacement battery |
| BWS-BAT01 |
| – |
| Replacement back shell, yellow |
| BWS-BC1 |
| Replacement back shell, black |
| BWS-BC1B |
| Replacement buzzer sealing ring |
| BWS-HS-1 |
| Replacement front shell |
| BWS-FC1 |
| Replacement LCD |
| BWS-LCD |
| Replacement vibrator |
| GA-VM-2 |
| Replacement 4-Series sensor sealing rings (kit of 10) |
| BWS-ORING-4S-K1 |
| Replacement 1-Series sensor o-rings (kit of 10) |
| BWS-ORING-1S-K1 |
| Replacement 4-Series sensor fixer kit |
| BWS-4SC-1 |
| Replacement 1-Series sensor fixer kit |
| BWS-WSC-1 |
| Replacement sensor screens (kit of 10) |
| BWS-SS |
| Replacement sensor fixer screws (kit of 25) |
| BWS-SCREW-K1 |
| Replacement 4-Series front cover |
| BWS-4C-1 |
| – |
| Replacement 1-Series front cover |
| BWS-WC-1 |
| Replacement PCB, chlorine (Cl2), non-wireless |
| BWS-C-PCB1 |
| Replacement PCB, chlorine dioxide (ClO2), non-wireless |
| BWS-V-PCB1 |
| Replacement PCB, carbon monoxide (CO), non-wireless |
| BWS-ML-PCB1 |
| Replacement PCB, carbon monoxide, hydrogen (h2) resistant (CO-H), non-wireless |
| BWS-M2-PCB1 |
| Replacement PCB, ethylene oxide (ETO), non-wireless |
| BWS-E-PCB1 |
| Replacement PCB, hydrogen (H2), non-wireless |
| BWS-R-PCB1 |
| Replacement PCB, hydrogen sulfide (H2S), non-wireless |
| BWS-HL-PCB1 |
| Replacement PCB, hydrogen sulfide (H2S), extended range, non-wireless |
| BWS-H-2-PCB1 |
| Replacement PCB, hydrogen cyanide (HCN), non-wireless |
| BWS-Z-PCB1 |
| Replacement PCB, ammonia (NH3), non-wireless |
| BWS-A-PCB1 |
| Replacement PCB, ammonia (NH3), extended range, non-wireless |
| BWS-A2-PCB1 |
| Replacement PCB, nitric oxide (NO), non-wireless |
| BWS-N-PCB1 |
| Replacement PCB, nitrogen dioxide (NO2), non-wireless |
| BWS-D-PCB1 |
| Replacement PCB, oxygen (O2), non-wireless |
| BWS-XL-PCB1 |
| Replacement PCB, ozone (O3), non-wireless |
| BWS-G-PCB1 |
| Replacement PCB, phosphine (PH3), non-wireless |
| BWS-P-PCB1 |
| Replacement PCB, sulfur dioxide (SO2), non-wireless |
| BWS-S-PCB1 |
| Replacement PCB, chlorine (Cl2), wireless |
| BWS1-C-PCB1 |
| Replacement PCB, chlorine dioxide (ClO2), wireless |
| BWS1-V-PCB1 |
| Replacement PCB, carbon monoxide (CO), wireless |
| BWS1-ML-PCB1 |
| Replacement PCB, carbon monoxide, hydrogen (h2) resistant (CO-H), wireless |
| BWS1-M2-PCB1 |
| Replacement PCB, ethylene oxide (ETO), wireless |
| BWS1-E-PCB1 |
| Replacement PCB, hydrogen (H2), wireless |
| BWS1-R-PCB1 |
| Replacement PCB, hydrogen sulfide (H2S), wireless |
| BWS1-HL-PCB1 |
| Replacement PCB, hydrogen sulfide (H2S), extended range, wireless |
| BWS1-H-2-PCB1 |
| Replacement PCB, hydrogen cyanide (HCN), wireless |
| BWS1-Z-PCB1 |
| Replacement PCB, ammonia (NH3), wireless |
| BWS1-A-PCB1 |
| Replacement PCB, ammonia (NH3), extended range, wireless |
| BWS1-A2-PCB1 |
| Replacement PCB, nitric oxide (NO), wireless |
| BWS1-N-PCB1 |
| Replacement PCB, nitrogen dioxide (NO2), wireless |
| BWS1-D-PCB1 |
| Replacement PCB, oxygen (O2), wireless |
| BWS1-XL-PCB1 |
| Replacement PCB, ozone (O3), wireless |
| BWS1-G-PCB1 |
| Replacement PCB, phosphine (PH3), wireless |
| BWS1-P-PCB1 |
| Replacement PCB, sulfur dioxide (SO2), wireless |
| BWS1-S-PCB1 |
| Replacement PCB, chlorine (Cl2), Lite |
| BWS2-C-PCB1 |
| Replacement PCB, chlorine dioxide (ClO2), Lite |
| BWS2-V-PCB1 |
| Replacement PCB, carbon monoxide (CO), Lite |
| BWS2-M-PCB1 |
| Replacement PCB, carbon monoxide, hydrogen (h2) resistant (CO-H), Lite |
| BWS2-M2-PCB1 |
| Replacement PCB, ethylene oxide (ETO), Lite |
| BWS2-E-PCB1 |
| Replacement PCB, hydrogen (H2), Lite |
| BWS2-R-PCB1 |
| Replacement PCB, hydrogen sulfide (H2S), Lite |
| BWS2-H-PCB1 |
| Replacement PCB, hydrogen sulfide (H2S), extended range, Lite |
| BWS2-H2-PCB1 |
| Replacement PCB, hydrogen cyanide (HCN), Lite |
| BWS2-Z-PCB1 |
| Replacement PCB, ammonia (NH3), Lite |
| BWS2-A-PCB1 |
| Replacement PCB, ammonia (NH3), extended range, Lite |
| BWS2-A2-PCB1 |
| Replacement PCB, nitric oxide (NO), Lite |
| BWS2-N-PCB1 |
| Replacement PCB, nitrogen dioxide (NO2), Lite |
| BWS2-D-PCB1 |
| Replacement PCB, oxygen (O2), Lite |
| BWS2-X-PCB1 |
| Replacement PCB, ozone (O3), Lite |
| BWS2-G-PCB1 |
| Replacement PCB, phosphine (PH3), Lite |
| BWS2-P-PCB1 |
| Replacement PCB, sulfur dioxide (SO2), Lite |
| BWS2-S-PCB1 |




if you are intersted in more Allen-Bradley product, Please feel free to contct below contact me :windy@hkxytech.com
Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website: http://www.hkxytech.com/ | GMT/UTC +8