New original YOKOGAWA Analog Input Module SAI143-S03-S3 In Stock


Yokogawa SAI143 Analog Input Module is a 16 channels isolated Analog Input Module for 4 to 20mA Current Input signals.

Brand: Yokogawa

Place of origin: Singapore


instrument or valve positioners, HART communication function is optional. Three types of connection selectable as Pressure clamp terminal, MIL connector cable or dedicated cable KS1, Dual-redundant communication is available by installing two communication modules on the same unit.


2. Standard Specification


Main Characters

Description

Number of input   channels

16, isolated

Input signal

4 to 20 mA

Allowable input current

0 to 25 mA

Withstanding voltage

1.5 kV AC between input signal and system for 1   minute

Data update frequency

40 ms

Transmitter power   supply

16.15 V minimum (at 20   mA), 26.4 V maximum (at 0 mA)

Setting of 2-wire or   4-wire transmitter

Individual channel   setting, Changed by setting pins

Temperature drift

±16 μA per 10 ˚C

Maximum current   consumption

320 mA (5 V DC), 550 mA   (24 V DC)

External connection

Pressure clamp   terminal, MIL connector cable, dedicated cable (KS1)

HART communication

Available

*1: No Zener barriers can be connected to this module. An isolation barrier should be used when an intrinsic safety instrumented system is used. 

*2: 500 V AC when dedicated signal cable is used. 

*3: ±32 µA (input range under 0.05 mA) (Style code S3 or later) 

*4: Rated accuracy of style code S3 or later is ±16 µA (Input range 0.05 to 23 mA). Rated accuracy of style code S2 or earlier is ±16 µA (Input range 1 to 23 mA). 

*5: When SAI143-S3 or SAI143-HC is used in the ambient temperature more than 60°C, number of input channels which a user can use is restricted. Refer to “ProSafe-RS Outline of I/O Modules (for FIO)” (GS 32P06K60-01EN). 

*6: The maximum voltage drop in the input protection circuit is 0.45 V. The module input impedance varies from 272.5 Ω (20 mA) to 362.5 Ω (4 mA). 

*7: This function enables to reset the alarm state of Fire and Gas devices by turning off the transmitter power supplied from this module in 2-wire setting. Supported by R4.03.00 or later and style code S4 or later


3. Model Selection of AAI143 Analog Input Modules

Model

Suffix Codes

Description

SAI143





Analog Input Module (4 to 20 mA, 16-channel, Isolated)


-S




Standard type


-H




With HART communication [Release: R1.02.00]



5



For pressure clamp terminal block or MIL cable with no explosion   protection



6



With signal cable interface adapter and no explosion protection



E



For pressure clamp terminal block or MIL cable with explosion protection



F



With signal cable   interface adapter and explosion protection




3


With ISA Standard G3   and temperature (-20 to 70 ºC)




C


With ISA Standard G3   and high-density installation (-20 to 70 ºC)

Option Code

/A4S00

With pressure clamp terminal block for analog [Model:   STA4S-00]

/A4S10

With pressure clamp terminal block for analog   (with surge absorber) [Model: STA4S-10]

/A4D00

With dual-redundant pressure clamp terminal   block for analog [Model: STA4D-00]

/A4D10

With dual-redundant pressure clamp terminal block   for analog (with surge absorber) [Part name: STA4D-10]

/PRP

With prevention pin of   false insertion

/CCC01

With connector cover for MIL cable (for flat   ribbon cable) [Model: SCCC01]


4.Typical Order Codes

Typical order codes

Remarks

SAI143-S53

Standard type

SAI143-S63

Standard type with KS interface adaptor

SAI143-H53

Hart   type

SAI143-H63

Hart type with KS interface adaptor


5. HART Communication
Analog I/O module with HART communication on ProSafe-RS allows Plant Resource Manager (PRM) to manage the HART communication devices connected to input and output modules on SCS. Also, the analog output module allows PRM client to conduct Partial Stroke Test (PST) on HART-supported valve positioner equipped with the PST function.
The HART communication functions on ProSafe-RS are interference-free and have no impact on the safety functions on SCS.

01


6. External Dimension

02

Hot Tags: SAI143, China, Yokogawa, suppliers, price, quotation, contractor, revamping, engineering, upgrading, installation, commissioning, immigration, integrator, configuration, programming, Analog input Module




YOKOGAWA SAI143

SAI143

 

 

 

SAI143 Analog Input Module (4 to 20 mA, 16-channel, module isolation)

SAI143-S53/A4S00 , SAI143-S53/A4S10 , SAI143-S53/A4D00 , SAI143-S53/A4D10 ,SAI143-S53/PRP, SAI143-S53/CCC01

SAI143-S63/A4S00 , SAI143-S63/A4S10 , SAI143-S63/A4D00 , SAI143-S63/A4D10 ,SAI143-S63/PRP, SAI143-S63/CCC01

SAI143-SE3/A4S00 , SAI143-SE3/A4S10 , SAI143-SE3/A4D00 , SAI143-SE3/A4D10 ,SAI143-SE3/PRP, SAI143-SE3/CCC01

SAI143-SF3/A4S00 , SAI143-SF3/A4S10 , SAI143-SF3/A4D00 , SAI143-SF3/A4D10 ,SAI143-SF3/PRP, SAI143-SF3/CCC01

SAI143-S5C/A4S00 , SAI143-S5C/A4S10 , SAI143-S5C/A4D00 , SAI143-S5C/A4D10 ,SAI143-S5C/PRP, SAI143-S5C/CCC01

SAI143-S6C/A4S00 , SAI143-S6C/A4S10 , SAI143-S6C/A4D00 , SAI143-S6C/A4D10 ,SAI143-S6C/PRP, SAI143-S6C/CCC01

SAI143-SEC/A4S00 , SAI143-SEC/A4S10 , SAI143-SEC/A4D00 , SAI143-SEC/A4D10 ,SAI143-SEC/PRP, SAI143-SEC/CCC01

SAI143-SFC/A4S00 , SAI143-SFC/A4S10 , SAI143-SFC/A4D00 , SAI143-SFC/A4D10 ,SAI143-SFC/PRP, SAI143-SFC/CCC01


PDE AND BRE


if you are intersted in more YOKOGAWA  product, Please feel free to contct below contact me :windy@hkxytech.com 


Windy Wang 
HONGKONG XIEYUAN TECH CO., LIMITED  
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com 
Website:  http://www.hkxytech.com/   | GMT/UTC +8


Related Products