Encoder
IFM Switched-mode power supply 24 V DC DN4012 PSU-1AC/24VDC-5A

IFM Switched-mode power supply 24 V DC DN4012 PSU-1AC/24VDC-5A

Model: DN4012

$1.00

Supplier: IFM

Categories: Encoder

After sales service. If you have any questions, click here.

Product Description

IFM Switched-mode power supply 24 V DC DN4012 PSU-1AC/24VDC-5A


DN4012


  • For the regulated power supply for controllers, sensors, actuators, and industrial electronics

  • Low power loss thanks to high efficiency

  • High mains buffering time

  • Particularly space-saving design

  • High power reserves

Electrical data
Frequency AC [Hz]47...64
Operating voltage tolerance [%]10
Operating voltage tolerance 2 [%]10
Operating voltage [V]automatic range selection
Nominal voltage AC [V]< 230
Input voltage range AC [V]100...120 / 200...240; (automatic range selection)
Output voltage DC [V]24...28
Protection classI; (IEC 61140)
Overvoltage protectionyes; (< 39 DC)
Output voltage [V]adjustable; output voltage to SELV, PELV
Max. output current at min. output voltage [A]5
Max. output current at max. output voltage [A]4.3
Max. output current peak at min. output voltage [A]6
Max. output current peak at max. output voltage [A]5.1
Output power (permanent) [W]120
Output power (peak) [W]144
Note on output power (peak)≤ 45 °C permitted continuously; > 45 °C < 1 minute every 10 minutes
Power factor (nominal voltage 120 V AC / 60 Hz)0.56
Power factor (nominal voltage 230 V AC / 50 Hz)0.47
Power reserve [%]20
Number of output circuits1
Max. residual ripple [mV]50
Switch-on peak current (nominal voltage 120 V AC / 60 Hz) [A]3
Switch-on peak current (nominal voltage 230 V AC / 50 Hz) [A]3
Inrush current limitationyes
Efficiency (nominal voltage 120 V AC / 60 Hz) [%]89.4
Efficiency (nominal voltage 230 V AC / 50 Hz) [%]90.2
External input protection≤ B-10 A / ≤ C-6 A
Derating [W/K]3 (60...70 °C)
Mains buffering time (nominal voltage 120 V AC / 60 Hz) [ms]80
Mains buffering time (nominal voltage 230 V AC / 50 Hz) [ms]78
Input current (nominal voltage 120 V AC / 60 Hz) [A]2.05
Input current (nominal voltage 230 V AC / 50 Hz) [A]1.23
Power loss (nominal voltage 120 V AC / 60 Hz) [W]14.5
Power loss (nominal voltage 230 V AC / 50 Hz) [W]13.2
Back feeding protection [V]35
Outputs
Short-circuit proofyes
Overload protectionyes
Overload performanceoutput current constant
Parallel connection of outputs possibleno
Series connection of outputs possibleyes
Operating conditions
Ambient temperature [°C]-25...70
Note on ambient temperatureobserve the free space for convection (see operating instructions)
Storage temperature [°C]-40...85
Max. relative air humidity [%]95; (IEC 60068-2-30)
ProtectionIP 20; (EN 60529)
Degree of soiling2; (IEC 62103: conductive soiling not permitted)
Tests / approvals
EMCEN 61000-6-1EN 61000-6-2EN 61000-6-4
Vibration resistanceIEC 60068-2-6±1,6 mm 2...17,8 Hz / 2 g 17,8...500 Hz
Shock resistanceIEC 60068-2-2730 g 6 ms / 20 g 11 ms
Mechanical data
Weight [g]594.5
Type of mountingrail; (TH35 (EN 60715))
Dimensions [mm]124 x 40 x 122.5
Materialssteel sheet
Displays / operating elements
DisplayDC ok1 x LED
Remarks
RemarksSeries connection of outputs only applies to identical units up to max. 150 V DC overall voltage100 V AC mains power and permanent P > 120 W may result in thermal shutdown.
Pack quantity1 pcs.
Electrical connection
Connectionscrew terminals:
Diagrams and graphs
block diagram
output characteristics
characteristic curve for degree of efficiency / power loss
characteristic line for derating
characteristic line for mains buffering time


24 V DC power supplies

ifm power supplies for control cabinet installation provide power to the connected controllers, sensors and actuators. They provide high noise immunity and sufficient power reserves to reliably handle short current spikes.
The compact housing takes up very little space in the control cabinet. Thanks to their high degree of efficiency, the units save energy costs and reduce waste heat in the control cabinet.


Related products


DN4012< 230 V24...28 V5 A4.3 A

DN4011< 230 V24...28 V3.3 A2.7 A

DN1030< 230 V24...28 V1.25 A

DN4014< 230 V24...28 V20 A17.1 A

DN1031< 230 V24...28 V2.5 A

DN4034< 400 V24...28 V20 A17.5 A

DN4033< 400 V24...28 V10 A8.6 A

DN4032< 400 V24...28 V5 A4.3 A

E84036< 400 V24...28 V40 A34.3 A

E84016< 230 V24...28 V40 A34.3 A

DN1023100...240 V12...15 V4.5 A3.6 A

DN1022< 230 V24...28 V4.1 A

DN1020< 230 V24...28 V1.3 A

E304069...27 V

DN030224 V4 A

DN2036400...500 V24...28 V30 A

E8012124 V

E8012024 V


Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website: http://www.hkxytech.com/ | GMT/UTC +8


Related Products