IFM Magnetic-inductive flow meter SM0504 SMR11GGX50KG/US100

| Product characteristics | |
|---|---|
| Number of inputs and outputs | Number of analog outputs: 2 |
| Measuring range | 6...1800 gph0.1...30 gpm |
| Process connection | threaded connection G 1 DN25 flat seal |
| Application | |
| System | gold-plated contacts |
| Application | for industrial applications |
| Installation | connection to pipe by means of an adapter |
| Media | Conductive liquids; water; water-based media |
| Note on media | conductivity: ≥ 20 µS/cmviscosity: < 70 mm²/s (40 °C) |
| Medium temperature [°F] | 14...158 |
| Pressure rating [bar] | 16 |
| Pressure rating [psi] | 232 |
| Electrical data | |
| Operating voltage [V] | 18...30 DC; (according to EN 50178 SELV/PELV) |
| Current consumption [mA] | 95; (24 V) |
| Min. insulation resistance [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 5 |
| Inputs / outputs | |
| Number of inputs and outputs | Number of analog outputs: 2 |
| Outputs | |
| Total number of outputs | 2 |
| Output signal | analog signal |
| Number of analog outputs | 2 |
| Analog current output [mA] | 4...20; (scalable) |
| Max. load [Ω] | 500 |
| Overload protection | yes |
| Measuring/setting range | |
| Measuring range | 6...1800 gph0.1...30 gpm |
| Display range | -1902...1902 gph-31.7...31.7 gpm |
| Resolution | 2 gph0.05 gpm |
| Analog start point ASP | 0...1268 gph0...21.15 gpm |
| Analog end point AEP | 318...1800 gph5.3...30 gpm |
| In steps of | 2 gph0.05 gpm |
| Temperature monitoring | |
| Measuring range [°F] | -4...176 |
| Resolution [°F] | 0.5 |
| Analog start point [°F] | -4...140.5 |
| Analog end point [°F] | 31.5...176 |
| In steps of [°F] | 0.5 |
| Accuracy / deviations | |
| Flow monitoring | |
| Accuracy (in the measuring range) | ± (0,8 % MW + 0,5 % MEW) |
| Repeatability | ± 0,2% MEW |
| Temperature monitoring | |
| Accuracy [K] | ± 4,5 (Q > 0,26 gpm) |
| Reaction times | |
| Flow monitoring | |
| Response time [s] | 0.15; (dAP = 0) |
| Damping for the switching output dAP [s] | 0...5 |
| Temperature monitoring | |
| Dynamic response T05 / T09 [s] | T09 = 20 (Q > 0,26 gpm) |
| Operating conditions | |
| Ambient temperature [°F] | 14...140 |
| Storage temperature [°F] | -13...176 |
| Protection | IP 67 |
| Tests / approvals | |
| EMC | DIN EN 60947-5-9500 V withstand voltage (V DC) |
| Shock resistance | DIN IEC 68-2-2720 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-65 g (10...2000 Hz) |
| MTTF [years] | 175 |
| Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
| Mechanical data | |
| Weight [g] | 612 |
| Material | stainless steel (1.4404 / 316L); PBT-GF20; PC; EPDM/X |
| Materials (wetted parts) | stainless steel (1.4404 / 316L); Hastelloy; PEEK; FKM |
| Process connection | threaded connection G 1 DN25 flat seal |
| Displays / operating elements | |
| Display | Display unit6 x LED, green (l/min, m³/h, gpm, gph, °C, °F)Measured valuesalphanumeric display, 4-digitProgrammingalphanumeric display, 4-digit |
| Display unit | l/min; m³/h; gpm; gph; °C; °F |
| Remarks | |
| Remarks | MW = Measured valueMEW = Final value of the measuring range |
| Pack quantity | 1 pcs. |
| Electrical connection | |
| Connection | Connector: 1 x M12; Contacts: gold-plated |
| Diagrams and graphs | |
| Pressure loss | ![]() dPPressure lossQvolumetric flow quantity |
Windy Wang
HONGKONG XIEYUAN TECH CO., LIMITED
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan,China
Tel: +86-27-8588 3233 | Fax:+86-27-8530 9780 | Mobile/Whatsapp :+86 15972199006 | Skype: windy@hkxytech.com
Mail: windy@hkxytech.com
Website: http://www.hkxytech.com/ | GMT/UTC +8